Equipment Database

  • Our searchable equipment database is designed to provide specific information on Core Labs instruments.

  • List Url
  • Page Size

Search equipment by core lab Select from the below dropdown boxes, and then click 'Search'

  • Core Lab *
  • Service Area
  • Lab Area

Total equipment found: 13

  • Imaging and Characterization Core Lab
    NMR


    400M SB Liquid NMR_iac
    NMR spectrometer dedicated to routine solution-state NMR applications. It is equipped with a BACS-60 sample changer and a default 5 mm Z-gradient 2-channel Broad Band BBFO probehead BB(F)-H-D for observation of nuclei in the range 15N to 31P plus 19F with 1H decouling/observe capable of a variable temperature range of -80 to +130 deg.C. It also features a 5 mm inverse triple resonance TBI 1H/13C/BB(109Ag to 31P) with variable temperature range of -150 to +150 deg.C. It is capable of performing routine automation with a 60-sample changer and of acquiring spectra on low frequency nuclei with a TBI probe.
    Sample - regular solution NMR samples in deuterated solvent with normal sample volume, normal viscosity, moderate to high sample concentration.

    Manufacturer: Bruker
    Model Number: Avance III 400 MHz
    Location: Building 3, Level 0 West

  • Imaging and Characterization Core Lab
    NMR


    400M WBA Solid NMR_iac
    NMR spectrometer dedicated to solid-state NMR applications. This instrument is equipped with a 3.2 mm triple resonance X/Y/H (X=13C, Y=15N to 2H) CP-MAS probe with spinning speed capability up to 24 kHz; and a 4 mm triple resonance X/Y/H (15N-31P/15N-2H/1H) CPMAS probe with spinning speed of 15 kHz. Both probes have a variable temperature range of -140 to +150 deg.C.
    Sample - powders, crystalline or amorphous materials.

    Manufacturer: Bruker
    Model Number: Avance III 400 MHz Wide Bore
    Location: Building 3, Level 0 West

  • Imaging and Characterization Core Lab
    NMR


    400M WBB Solid NMR_iac
    NMR spectrometer dedicated to solid-state NMR applications. This instrument is equipped with a 4 mm high temperature H/X (X=15N-31P) CP-MAS probe with spinning speed capability of up to 15 kHz and variable temperature range from -120 to +300 deg.C; a 3.2 mm triple resonance X/Y/H (X=13C, Y=15N to 2H) CP-MAS probe with spinning speed capability up to 24 kHz; and a 7 mm double resonance H/X (X=15N-31P) CPMAS probe capable of spinning speed of 7 kHz with a variable temperature range of -120 to +150 deg.C.
    Sample - powders, crystalline or amorphous materials.

    Manufacturer: Bruker
    Model Number: Avance III 400 MHz
    Location: Building 3, Level 0 West

  • Imaging and Characterization Core Lab
    NMR


    500M SB Liquid NMR_iac
    NMR spectrometer dedicated for solution-state NMR applications. The default probe is a 5mm BBFO Broadbanded observe Cryoprobe with highest sensitivity on the broadest range of nuclei in the range of 31P to 15N (excluding between 199Hg and 153Eu). It is also equipped with a 5 mm triple inverse TCI H-C/N-D-05-Z cryoprobe for highest sensitivity for proton inverse spectroscopy, and superior sensitivity for 13C; 15N direct detection not recommended. This instrument is also equipped with a 5 mm inverse triple resonance 1H/13C/15N TXI probe.
    Sample - solution-state of low to high concentration, normal liquid viscosity, normal sample volume. For custom service, protein samples or other samples requiring proper calibrations.

    Manufacturer: Bruker
    Model Number: Avance III 500 MHz NMR
    Location: Building 3, Level 0 West

  • Imaging and Characterization Core Lab
    NMR


    500M SWB Imaging NMR_iac
    SWB magnetic resonance imaging - MRI - equipped with a Mini Imaging Quadrature 1H probehead using a birdcage coil. 
    Sample - material with up to 6cm diameter to fit the sample container.

    Manufacturer: Bruker
    Model Number: Avance III 500 MHz MRI Biospec
    Location: Building 3, Level 0 West

  • Imaging and Characterization Core Lab
    NMR


    600M SB Liquid NMR_iac

    NMR spectrometer system dedicated to broadband solution-state NMR applications, and variable temperature NMR operation.

    The default probe is a 5 mm Z-gradient SmartProbe BB(F)-H-D for observation of 19F with 1H decoupling; and capable of observation of nuclei in the range 15N to 31P with 1H decoupling, and a variable temperature range of -150 to +150 deg. This instrument is also equipped with a 5 mm Z-gradient broadband probehead BBO capable of observation of nuclei in the range 109Ag to 31P with 1H decoupling, and a variable temperature range of -150 to +180 deg. C. This instrument is also equipped with a backup 5 mm triple inverse TCI H-C/N-D-05-Z cryoprobe and 10 mm high temperature DCH cryoprobe capable of a VT limit of 135 deg.C, and a BACS-60 sample changer. Lastly, this instrument is also equipped with a Diff-30 diffusion probe and gradient accessory.


    Sample - solution-state of low to high concentration, normal liquid viscosity, and normal sample volume.

    Manufacturer: Bruker
    Model Number: Avance III 600 MHz
    Location: Building 3, Level 0 West

  • Imaging and Characterization Core Lab
    NMR


    600M WB Solid NMR_iac

    NMR spectrometer system dedicated to solid-state NMR applications. This instrument is equipped with four cross polarization magic angle spinning (CPMAS) probes: a 3.2 CP-MAS X/Y/H (13C/15N-2H/1H) triple resonance probe capable of spinning speed up to 24 kHz; a 4mm CPMAS X/Y/H (low-gamma) with specialized inserts; and two 2.5 mm 1H/19F/X (one with X=N-C) and (one with X=N-P) triple resonance CP-MAS probe capable of spinning speed up to 35 kHz. Both probes have variable temperature range of -140 to +150 deg.C. It is also equipped with a 4 mm high-resolution-MAS (HR-MAS) 1H/13C dual inverse probe.


    Sample - powders, crystalline or amorphous materials, and inhomogeneous solution samples.

    Manufacturer: Bruker
    Model Number: Avance III 600 MHz
    Location: Building 3, Level 0 West

  • Imaging and Characterization Core Lab
    NMR


    700M SB Liquid NMR_iac
    NMR spectrometer system dedicated to solution-state NMR applications. The default probe is a 5 mm triple resonance inverse TCI H-C/N-D cryoprobe with ATM & Z-gradient. The magnet is equipped with a 5 mm Quadrupole Inverse or QXI for 1H/31P/13C/15N observation capable of VT operation from -150 to +180 deg.C and automatic tuning and matching; and with a high throughput sample changer for up to 5x96 tubes.
    Sample - solution-state of low to high concentration, normal liquid viscosity, normal sample volume, protein samples, or samples requiring accurate or proper calibrations.

    Manufacturer: Bruker
    Model Number: Avance NEO 700
    Location: Building 3, Level 0 West

  • Imaging and Characterization Core Lab
    NMR


    900M WB Solid NMR_iac
    NMR spectrometer system dedicated to solid state NMR experiments. The magnet is equipped with 6 different CPMAS probes. It is equipped with a CPMAS triple resonance high speed 1.3mm probe with a tuning range of 15N-13 deg.C on X/Y plus 1H capable of a sample temperature of -70 to +80 deg.C. The default probe is a CPMAS triple resonance 3.2mm probe, maximum spinning speed of 24kHz, with one H/C/N insert for applications with 1H decoupling only, and a variable temperature range of -140 to +150 deg.C.; a 3.2mm H/F-X (X=15N-31P) CPMAS probe, maximum spinning speed of 24 kHz; a 4.0 mm low-gamma H/X (X=13C, 15N-32.8 MHz) probe for low frequency nuclei, maximum spinning speed of 15 kHz; a 2.5mm H/X/Y CPMAS probe with exchangeable inserts for X and Y and 35 KHz maximum spinning speed; and a 3.2mm 13C/15/1H E-free CPMAS probe with maximum spinning speed of 24 kHz and a temperature range of -80 to +80 deg.C.
    Sample - powders, and crystalline or amorphous materials.

    Manufacturer: Bruker
    Model Number: Avance III 900 MHz
    Location: Building 3, Level 0 West

  • Imaging and Characterization Core Lab
    NMR


    950M SB Liquid NMR_iac
    NMR spectrometer dedicated to solution-state biomolecular NMR applications. It is equipped with a triple resonance inverse 1H-13C-15N 5 mm TCI cryoprobe offering the highest sensitivity for 1H-detected NMR applications. An additional probe includes a 5 mm TXI probe for 1H-13C-15N experiments.
    Sample - solution-state of low to high concentration, normal liquid viscosity, normal sample volume.

    Manufacturer: Bruker
    Model Number: Avance NEO 950 MHz
    Location: Building 3, Level 0 West