Radiation Labeling Core Lab Radiation Labeling

2470 Automatic Gamma Counter

WIZARD2™ automatic gamma counter is the next generation instrumentation designed for counting performance with all types of samples and for every gamma counting application. Unique 10 well-type detectors and sample changer system, advanced robotics, and highly effective lead shielding result in high counting efficiency, low background and minimal crosstalk.
The radionuclide library consist of 45 nuclides including 22-Sodium, 129-Iodine and 51-Chromium

Perkin Elmer
2470-0200
Building 7, Level 2
Analytical Chemistry Core Lab Solids

Fourier Transform Infrared Spectroscope_Nicolet iS50R

Performs chemical analyses of sample materials by collecting data (transmission and reflection) in the far-IR, mid-IR, and near-IR spectral ranges using a variety of accessories.
Sample - powders, solids, thin films, gas, liquids. DRIFT can measure solid, powder, or polymer samples. Quantity to be discussed with lab scientist.

Thermo Fisher Scientific
Nicolet iS50R
Building 3, Level 3 East
Prototyping and Product Development Core Lab Central Fabrication Lab

Table Saw

Delta Unisaw is a 10" (254 mm) left-tilting saw with a 5/8" (16mm) arbor.
Specifications:
Max depth of cut at 90 degrees - 79mm ;
Max depth of cut at 45 degrees - 54mm ;
Max rip to right of blade - 1321mm ;
Max rip to left of blade - 305mm ;
Max width of dado - 25.4mm

Delta Machinery
36-L500
Building 4, Level 0 West
Analytical Chemistry Core Lab Inorganics

Bruker S8 Tiger WDXRF

Nondestructive technique to determine elemental composition
Sample - solids, powder or liquids.

Bruker
S8 Tiger A15X10
Building 3, Level 3 East
Prototyping and Product Development Core Lab Central Fabrication Lab

DMG MORI SLM 30

The LASERTEC 30 SLM can achieve highly accurate additive manufacturing of 3D parts with a layer volume of 300 × 300 × 300 mm and a layer thickness of 20 to 100 μm using Selective Laser Melting - SLM. The machine is especially suitable for production of high-mix, low-volume parts or complex-shaped workpieces.

DMG MORI
Lasertech SLM30
Building 4, Level 0 West
Bioscience Core Lab Proteomics and Protein Expression

Direct Detect Spectrometer

Direct Detect Spectrometer for protein concentration determination by infrared spectrometry

Merck Millipore
DDHW00010-00
Building 2, Level 2 East
Bioscience Core Lab Proteomics and Protein Expression

Biosafety Cabinet Class II, Type A2_2010552

Biosafety Cabinet for aseptic handling of cultured cells

Nuaire
NU-425 400G
Building 2, Level 2 East
Radiation Labeling Core Lab Radiation Labeling

Liquid Scintillation Counter 3

The Tri-Carb 4910TR liquid scintillation counter provides the popular standard features needed for radionuclide research applications and the versatility to expand for radioisotope labeling with the optional ultralow-level and alpha/beta discrimination features

Perkin Elmer
Tri-Carb 4910 TR
Building 7, Level 2
Bioscience Core Lab Capillary and Third Generation Sequencing

PacBio Sequel IIE

The Sequel IIe System is the latest technology offered by Pacific Biosciences (PacBio). It offers industry-leading, Single Molecule Real-Time (SMRT) sequencing, with highly accurate (>99.9%) reads (known as high fidelity, HiFi reads), equivalent to NGS and Sanger sequencing, with long read lengths (>10 Kb).
This technology is the basis for the recently published fully complete telomere-to-telomere human genome assembly and is the gold standard for genome assemblies, across all species, as well as metagenomic studies, RNA sequencing, targeted sequencing and other applications.

PacBio
Sequel IIE
Building 2, Level 2 east
Bioscience Core Lab NGS, qPCR and Single Cell Genomics

Tapestation-Post_PCR_bcl

The Agilent TapeStation system is an automated electrophoresis solution the quality control of DNA and RNA samples. It has the same feature of the Bioanalyzer with the advantage of increased throughout and therefore faster processing.
Sample type: DNA, RNA, NGS libraries

Agilent Technologies
G2991AA
Building 2, Level 2 East
Radiation Labeling Core Lab Radiation Labeling

Liquid Scintillation Counter 2

The Tri-Carb 4910TR liquid scintillation counter provides the popular standard features needed for radionuclide research applications and the versatility to expand for radioisotope labeling with the optional ultralow-level and alpha/beta discrimination features

Perkin Elmer
Tri-Carb 4910 TR
Building 7, Level 2
Bioscience Core Lab NGS, qPCR and Single Cell Genomics

Miseq System V2-2

The MiSeq sequencing System facilitates the research with a wide range of sequencing applications. It is capable of automated paired-end reads and up to 15 Gb per run, delivering over 600 bases of sequence data per read. The library prep kits that it uses are optimized for a variety of applications, including targeted gene, small genome, and amplicon sequencing, 16S metagenomics, and more. Illumina's Sequencing by Synthesis (SBS) technology uses a reversible-terminator method, with fluorescently labeled nucleotides to detect single bases as they are incorporated into growing DNA strands.
MiSeq is the only desktop sequencer that can produce 2 x 300 paired-end reads in a single run. This allows small genome sequencing and assembly, and enables detection of target variants with unmatched accuracy, especially within homopolymer regions
Read lengths: 2x300 (available here, for the full list please refer to Illumina instrument specifications).
Output: 15 Gb.
Sample type: any Illumina compatible library.

Illumina
Miseq
Building 2, Level 2 East
Bioscience Core Lab NGS, qPCR and Single Cell Genomics

Covaris M220-2_bcl

The Covaris M220 is designed for next-generation sequencing applications that require high-quality DNA fragmentation for library preparation. The Covaris M220 efficiently focuses the minimum amount of energy required directly into a sample, enabling precise control of the hydrodynamic shearing forces that fragment nucleic acids to the selected size.
Applications: DNA shearing for Next-Gen Sequencing.

Covaris, Inc
MM20
Building 2, Level 2 East
Bioscience Core Lab NGS, qPCR and Single Cell Genomics

LSR Fortessa

Flow cytometry instrument able detect physical and chemical characteristics of particles using laser, capable of accommodating the detection of up to 18 colors of fluorescents. The high throughput sampler can handle a 96 well plate.
Sample - cells or bacteria from sea water.

BD Biosciences
N/A
Building 2, Level 2 East
Bioscience Core Lab NGS, qPCR and Single Cell Genomics

KingFisher Duo Prime system

Kingfisher Duo Prime System allows the extraction of DNA, RNA and protein from many matrices, i.e. body fluids, plants, animals and bacteria. Extraction protocols are customizable. Specific kits and plasticware are not provided.

Thermo Fisher
706
Building 2, Level 2 East
Bioscience Core Lab NGS, qPCR and Single Cell Genomics

Bioanalyser-Post_PCR_bcl

The Agilent Bioanalyzer uses a micro-capillary based electrophoretic cell that allows rapid and sensitive investigation of nucleic acid samples. The instrument provides precise information on the fragment size distributions. Typical applications are: library QC, total RNA QC, small RNA QC
Sample type: DNA, RNA, NGS libraries

Agilent Technologies
G2938C
Building 2, Level 2 East
Bioscience Core Lab NGS, qPCR and Single Cell Genomics

BioMark HD

High-throughput microfluidics-based qPCR for DNA, RNA and miRNA analysis. Chip for 96 primers and 96 samples or 12 primers and 12 samples. Workflow can be couple with C1 using 96.96/12.12 IFC from Single Cell Capture module.
Sample - median cell size should be within the range of each chip (between 5 and 25 micron) and 166 to 250K cells / ml Total RNA, minimum 5 ng; RNA concentration 5 pg/ul or higher. Minimum volume, 10 ul.

Fluidigm
BioMark HD
Building 2, Level 2 East
Bioscience Core Lab Proteomics and Protein Expression

Ultra Centrifuge 2003386

Optima L-100K preparative ultracentrifuge is capable of performing large-volume separation more efficiently. Ideal for applications such as high-purity plasmid DNA, subcellular particles and virus isolations, this versatile floor model operates with a broad range of superb rotors, including zonal and continuous flow for large-volume separations.

Beckman Coulter, Inc.
Optima L-100K
Building 2, Level 2 East
Bioscience Core Lab Proteomics and Protein Expression

Typhoon Scanner

The Typhoon 9410 Imager is a multi-mode imager that produces digital images of radioactive, fluorescent or chemiluminescent samples with the capability of scanning using a 10um pixel size.
Sample - gels, microarray and a wide range of tagged and untagged samples.

GE Healthcare
Typhoon 9410
Building 2, Level 2 East
Bioscience Core Lab Proteomics and Protein Expression

Orbitrap Fusion Lumos

The Thermo Scientific™ Orbitrap Fusion™ Lumos™ Tribrid™ Mass Spectrometer is equipped with nano-LC system.
This instrument excels at the most challenging of applications, including low level PTM analysis, multiplexed relative quantitation using isobaric tags (TMT and iTRAQ), as well as MSn analysis of peptides.
This system incorporates a wide range of fragmentation techniques such as HCD, CID and ETD fragmentation.
In BCL, the Fusion Lumos is dedicated to bottom-up proteomics providing MS data from purified peptide mixtures with varying levels of complexity.

Thermo Fisher
Orbital Fusion Lumos
Building 2, Level 2 East